LinaTech Radiation Therapy Treatment Planning System



 

The LinaTech Radiation Therapy Treatment Planning System (WiMRT) is a clinically proven software system based on Microsoft Windows PC platform design. LinaTech performs three dimensional dose calculation and radiation treatment planning functions for conformal radiation including head, head and neck, and body procedures, as well as CT simulation procedures. Working together with a CT, CT/PET or CT/MRI, conformal lead block and multi-leaf collimators, LinaTech WiMRT performs intensity modulation radiation therapy (IMRT), quickly and effectively.

Advanced Calculation Model
LinaTech software uses the fast 3D Fourier transform convolution photon beam dose calculation model and fast 3D electron pencil beam dose calculation model. The calculation error is within 2%.


Practical Planning Functions

Provide routine conformal inverse radiation plan database to decline the planning time
3D static (step and shoot) and dynamic (sliding window) intensity modulation
3D virtual display which is helpful to review patient's focus area
Automatic calculation for the leaf position of MLC
Support various manufacturers MLC
3D automatic extraction of patient organ contouring
3D inhomogeneous tissue density correction
Support combined planning of non-planar and arc beam
Support combined planning of electron and photon beam
Automatic design and output for 3D irregular beam shape
Support 3D multi-isocenter planning
Support dynamic wedge
Machine data quality evaluation

Integrated Design
The LinaTech  WiMRT system consists of reliable and stable modules, such as the head, the head and neck, and the body, as well as CT simulation modules, which allows clinicians to choose exactly what they need now and allows for easy upgrading as needed and for future treatment protocols.

The LinaTech Treatment Planning system is extremely cost effective when compared to other planning systems and is designed to operate as a primary standalone system which can also integrate with other manufacturer's systems. The system can be used with the LinaTech DMLC and/or other manufacturers MLC's and is a complete solution for your treatment planning needs.

Please contact us at 1-800-543-5144 for more information or to arrange a complimentary web-based demonstration! 

Abstracts - PDF

Genetic Algorithm

Auto Beam

Particle Swarm Beam Angle

 

 

 

 

 
Acceletronics is the only independent linear accelerator service company that is registered
to the internationally recognized ISO 9001:2000 quality system standards.

Copyright © 2008 Acceletronics, Inc
.
All rights reserved. Terms &Conditions of Use All products mentioned are trademarks of their respective companies.